动态表 (Dynamic Table)
This page discusses these differences and explains how Flink can achieve the same semantics on unbounded data as a regular database engine on bounded data.
The following table compares traditional relational algebra and stream processing with respect to input data, execution, and output results.
Despite these differences, processing streams with relational queries and SQL is not impossible. Advanced relational database systems offer a feature called Materialized Views. A materialized view is defined as a SQL query, just like a regular virtual view. In contrast to a virtual view, a materialized view caches the result of the query such that the query does not need to be evaluated when the view is accessed. A common challenge for caching is to prevent a cache from serving outdated results. A materialized view becomes outdated when the base tables of its definition query are modified. Eager View Maintenance is a technique to update a materialized view as soon as its base tables are updated.
The connection between eager view maintenance and SQL queries on streams becomes obvious if we consider the following:
- A database table is the result of a stream of ,
UPDATE
, andDELETE
DML statements, often called changelog stream. - A materialized view is defined as a SQL query. In order to update the view, the query continuously processes the changelog streams of the view’s base relations.
- The materialized view is the result of the streaming SQL query.
With these points in mind, we introduce following concept of Dynamic tables in the next section.
Dynamic tables are the core concept of Flink’s Table API and SQL support for streaming data. In contrast to the static tables that represent batch data, dynamic tables are changing over time. They can be queried like static batch tables. Querying dynamic tables yields a Continuous Query. A continuous query never terminates and produces a dynamic table as result. The query continuously updates its (dynamic) result table to reflect the changes on its (dynamic) input tables. Essentially, a continuous query on a dynamic table is very similar to a query that defines a materialized view.
It is important to note that the result of a continuous query is always semantically equivalent to the result of the same query being executed in batch mode on a snapshot of the input tables.
The following figure visualizes the relationship of streams, dynamic tables, and continuous queries:
- A stream is converted into a dynamic table.
- A continuous query is evaluated on the dynamic table yielding a new dynamic table.
In the following, we will explain the concepts of dynamic tables and continuous queries with a stream of click events that have the following schema:
The following figure visualizes how the stream of click event (left-hand side) is converted into a table (right-hand side). The resulting table is continuously growing as more records of the click stream are inserted.
Note: A table which is defined on a stream is internally not materialized.
A continuous query is evaluated on a dynamic table and produces a new dynamic table as result. In contrast to a batch query, a continuous query never terminates and updates its result table according to the updates on its input tables. At any point in time, the result of a continuous query is semantically equivalent to the result of the same query being executed in batch mode on a snapshot of the input tables.
In the following we show two example queries on a clicks
table that is defined on the stream of click events.
The first query is a simple GROUP-BY COUNT
aggregation query. It groups the clicks
table on the user
field and counts the number of visited URLs. The following figure shows how the query is evaluated over time as the clicks
table is updated with additional rows.
When the query is started, the clicks
table (left-hand side) is empty. The query starts to compute the result table, when the first row is inserted into the clicks
table. After the first row [Mary, ./home]
was inserted, the result table (right-hand side, top) consists of a single row [Mary, 1]
. When the second row [Bob, ./cart]
is inserted into the clicks
table, the query updates the result table and inserts a new row [Bob, 1]
. The third row yields an update of an already computed result row such that [Mary, 1]
is updated to [Mary, 2]
. Finally, the query inserts a third row [Liz, 1]
into the result table, when the fourth row is appended to the clicks
table.
The second query is similar to the first one but groups the clicks
table in addition to the user
attribute also on an before it counts the number of URLs (time-based computations such as windows are based on special time attributes, which are discussed later.). Again, the figure shows the input and output at different points in time to visualize the changing nature of dynamic tables.
Although the two example queries appear to be quite similar (both compute a grouped count aggregate), they differ in one important aspect:
- The first query updates previously emitted results, i.e., the changelog stream that defines the result table contains
INSERT
andUPDATE
changes. - The second query only appends to the result table, i.e., the changelog stream of the result table only consists of changes.
Whether a query produces an append-only table or an updated table has some implications:
- Queries that produce update changes usually have to maintain more state (see the following section).
- The conversion of an append-only table into a stream is different from the conversion of an updated table (see the section).
Many, but not all, semantically valid queries can be evaluated as continuous queries on streams. Some queries are too expensive to compute, either due to the size of state that they need to maintain or because computing updates is too expensive.
- State Size: Continuous queries are evaluated on unbounded streams and are often supposed to run for weeks or months. Hence, the total amount of data that a continuous query processes can be very large. Queries that have to update previously emitted results need to maintain all emitted rows in order to be able to update them. For instance, the first example query needs to store the URL count for each user to be able to increase the count and sent out a new result when the input table receives a new row. If only registered users are tracked, the number of counts to maintain might not be too high. However, if non-registered users get a unique user name assigned, the number of counts to maintain would grow over time and might eventually cause the query to fail.
- Computing Updates: Some queries require to recompute and update a large fraction of the emitted result rows even if only a single input record is added or updated. Clearly, such queries are not well suited to be executed as continuous queries. An example is the following query which computes for each user a
RANK
based on the time of the last click. As soon as theclicks
table receives a new row, thelastAction
of the user is updated and a new rank must be computed. However since two rows cannot have the same rank, all lower ranked rows need to be updated as well.
The Query Configuration page discusses parameters to control the execution of continuous queries. Some parameters can be used to trade the size of maintained state for result accuracy.
A dynamic table can be continuously modified by INSERT
, UPDATE
, and DELETE
changes just like a regular database table. It might be a table with a single row, which is constantly updated, an insert-only table without UPDATE
and DELETE
modifications, or anything in between.
When converting a dynamic table into a stream or writing it to an external system, these changes need to be encoded. Flink’s Table API and SQL support three ways to encode the changes of a dynamic table:
Append-only stream: A dynamic table that is only modified by
INSERT
changes can be converted into a stream by emitting the inserted rows.Retract stream: A retract stream is a stream with two types of messages, add messages and retract messages. A dynamic table is converted into an retract stream by encoding an
INSERT
change as add message, aDELETE
change as retract message, and anUPDATE
change as a retract message for the updated (previous) row and an add message for the updating (new) row. The following figure visualizes the conversion of a dynamic table into a retract stream.
- Upsert stream: An upsert stream is a stream with two types of messages, upsert messages and delete messages. A dynamic table that is converted into an upsert stream requires a (possibly composite) unique key. A dynamic table with unique key is converted into a stream by encoding
INSERT
andUPDATE
changes as upsert messages andDELETE
changes as delete messages. The stream consuming operator needs to be aware of the unique key attribute in order to apply messages correctly. The main difference to a retract stream is thatUPDATE